The Nasopharyngeal Airway (NPA), often referred to as a "nasal trumpet," is a flexible, tube-like device inserted through a patient's nostril and into the posterior pharynx. It serves as a crucial airway adjunct, designed to maintain a patent (open) airway by creating a clear passage for airflow, bypassing potential obstructions in the nasopharynx and oropharynx.
1. Purpose and Indications
The NPA's primary purpose is to ensure airway patency, but its key advantage lies in the patient population it can be used for.
When is it used? An NPA is indicated for a patient who is:
- Conscious or semi-conscious with a compromised airway (e.g., due to snoring, stridor, or poor respiratory effort).
- Unconscious but has an intact gag reflex, making an Oropharyngeal Airway (OPA) unsafe.
- Unable to open their mouth sufficiently for OPA insertion due to conditions like trismus (lockjaw).
- In need of airway support during procedures or while being transported.
The NPA is generally better tolerated than an OPA in patients with some level of consciousness because it does not typically trigger the gag reflex. It is an excellent tool for relieving obstruction caused by the tongue falling back, but it does so from a different angle than the OPA.
2. Anatomy of the NPA
The NPA has a simple, specialized design for safe and effective nasal insertion.
- Flange (or Shoulder): The wider, flat end that remains outside the nostril. It prevents the device from being inserted too far and becoming lost in the nasopharynx.
- Body: The hollow, flexible tube that allows air to pass through. It is made of soft, pliable material (like PVC or silicone) to conform to the nasal passage and minimize trauma.
- Bevel (or Tip): The distal end of the tube. It is angled and beveled to facilitate smooth insertion along the floor of the nasal passage, reducing the risk of it getting caught on the nasal turbinates (bony structures inside the nose).
3. Sizing and Selection
Correct sizing is just as critical for the NPA as it is for the OPA.
- If the NPA is too short: It will not extend far enough to bypass the obstruction.
- If the NPA is too long: The tip can press against the epiglottis or the posterior wall of the pharynx, potentially stimulating the vagus nerve and causing bradycardia (slow heart rate), laryngospasm, or vomiting.
Method for Sizing: The standard method is to measure the NPA against the patient's face:
- Measure from the tip of the patient's nose to the tragus of their ear (the small, pointed cartilage in front of the ear canal).
- The selected NPA should be equal to or slightly shorter than this distance.
Diameter: The diameter of the tube should be appropriate for the size of the patient's nostril. A common clinical rule of thumb is that the NPA's diameter should be slightly smaller than the patient's little finger.
4. Contraindications
The contraindications for an NPA are absolute and must be strictly adhered to due to the risk of catastrophic injury.
Absolute Contraindications:
- Suspected or confirmed basilar skull fracture. This is the most critical contraindication. The cribriform plate (a thin bone at the roof of the nasal cavity) may be fractured. Inserting an NPA could push the device through this fracture and into the brain, causing severe, irreversible damage.
- Clinical signs of a basilar skull fracture include:
- Battle's Sign: Bruising behind the ears.
- Raccoon Eyes: Periorbital bruising (bruising around the eyes).
- CSF Rhinorrhea: Clear cerebrospinal fluid leaking from the nose.
- Severe nasal trauma or deformity.
- History of recent nasal surgery.
- Obstruction of the chosen nostril (e.g., from polyps, a foreign body, or severe septal deviation).
- Coagulopathy or bleeding disorders (due to the high risk of severe, uncontrollable nosebleeds/epistaxis).
5. Insertion Technique
Proper technique is essential to minimize trauma and complications.
Preparation:
- Assess for contraindications! This is the first and most important step.
- Select the appropriate size NPA.
- Lubricate the NPA generously with a water-based or anesthetic lubricant. This is non-negotiable to reduce friction and prevent mucosal trauma.
- Position the patient with their head in a neutral position (if no C-spine injury is suspected).
Insertion Steps:
- Inspect both nostrils and choose the one that appears most patent and less traumatized. The right nostril is often slightly larger.
- Hold the NPA like a pencil, with the bevel facing towards the septum (the middle part of the nose).
- Insert the tip gently but firmly, directing it perpendicular to the face (straight back, not upwards towards the bridge of the nose).
- Advance the NPA using a gentle, slow, twisting or screwing motion. This helps it navigate the curves of the nasal passage.
- Continue advancing until the flange rests flush against the patient's nostril.
- DO NOT USE FORCE. If you meet significant resistance, stop. Do not force it. Try the other nostril with a new, lubricated NPA or select a smaller size.
- After insertion, confirm patency by listening for airflow and observing for improved respiratory effort.
6. Potential Complications
Even with correct technique, complications can arise:
- Epistaxis (Nosebleed): The most common complication, caused by trauma to the richly vascularized nasal mucosa (Kiesselbach's plexus).
- Nasal Trauma: Laceration, perforation of the nasal septum, or damage to the turbinates.
- Vomiting and Aspiration: If the NPA is too long and stimulates the gag reflex.
- Intracranial Placement: The most devastating complication, occurring in patients with an undiagnosed basilar skull fracture.
- Infection: From improper cleaning or a prolonged indwelling time.
7. Role in Airway Management and Comparison to OPA
The NPA is an adjunctive airway device and a fundamental skill in BLS, ACLS, and PALS.
Conclusion
The Nasopharyngeal Airway is an invaluable and often underutilized tool in airway management. Its ability to provide a patent airway in patients who retain a gag reflex makes it a critical alternative to the OPA. However, its use demands a thorough patient assessment to rule out life-altering contraindications, particularly a basilar skull fracture. When used correctly with appropriate sizing, generous lubrication, and a gentle technique—the NPA is a safe, effective, and potentially life-saving device.